Contact Us
TEL: +86-0571-88334626
E-mail: sales@tacon-china.com.cn
Home > News > Content
Diethyl Oxalate Leakage Emergency Treatment
Jul 06, 2018

Quickly evacuate the personnel from the leakage area to the safe area, and conduct isolation, strictly restrict the access. Cut off the fire. Emergency personnel are advised to wear self - sufficient positive pressure respirators and wear antivirus clothing. Cut off the leakage source as much as possible to prevent access to restricted Spaces such as sewers and drains. Small leakage: adsorption or absorption by sand or other non-combustible materials. Also can be made of non-combustible dispersants of the emulsion scrubbing, after washing liquid dilution into the waste water system. Massive leakage: build a wall or dig a pit for shelter. Cover with foam to reduce steam hazards. Transfer by pump to tank car or special collector, recycle or transport to waste disposal site.